15
Checking the Operating Status using the
ICIM2
You can use the ICIM to check status of all operating parameters of a module. All
status information is displayed on the ICIM LCD.
1 At the MAIN menu, press the key to highlight the Shelf and Slot fields.
2 Press the key to address the Shelf number. Then press the key or the
key to scroll to the number of the desired shelf.
3 Press the key. The Slot field is highlighted.
4 Press the key or the key to scroll to the number of the desired slot.
5 Press the key. The MODULE menu appears on the ICIM LCD.
6 Press the key.
7 Press the key or the key to scroll through the monitored parameters
until you find the parameter of interest.
8 Check the status of the desired parameter or select other parameters to monitor.
When finished, press the key to return to the MAIN menu