Equal wattage power
supply is inserted with
redundancy enabled.
System log and syslog
messages are generated.
System power equals the
power capability of one
power supply that already
works.
No change in the module
status because the power
capability is unchanged.
Equal wattage power
supply is inserted with
combined mode enabled
(redundancy disabled).
System log and syslog
messages are generated.
System power is not the
sum of two power supplies.
It is P+ (P * ratio). Refer to
the Available Power for
Catalyst 4500 Series
Switches Power Supplies
section of the product
documentation for more
information.
The modules marked as
power−deny in the show
module command output
status field are brought up if
there is sufficient power.
Higher or lower wattage
power supply is inserted.
System log and syslog
messages are generated.
System power remains the
same.
The newly inserted power
supply is kept in
err−disabled mode.
No change in the module
status because the power
capability is unchanged.
Different type (AC/DC)
power supply is inserted.
System log and syslog
messages are generated.
System power remains the
same.
The newly inserted power
supply is kept in
err−disabled mode.
No change in the module
status because the power
capability is unchanged.
Power supply is removed
with redundancy enabled System log and syslog
messages are generated.