Chapter 1 Product Overview
Management Software
Audible alarms are turned off when you press the ACO button on the NI-2 card faceplate or clear
the alarm in the Cisco IOS software.
MINORA minor alarm condition is indicated when the MINOR LED in the NI-2 card faceplate
lights.
When a minor alarm occurs, the minor visual and audible alarm relays are also activated.
A small number of subscribers that are connected to the node are affected.
Minor alarms clear after you fix the condition that triggered the alarm.
Audible alarms are turned off when you press the ACO button on the NI-2 card faceplate or clear
the alarm in the Cisco IOS software.
Visual and audible alarm relay contacts can be wired from the Cisco 6260 to CO alarm devices (remote
lights or bells, for example) located anywhere within the facility.
The visual and audible alarm relays are located on the I/O module, but the NI-2 card hardware operates
them.
For more information about alarms that are generated in the management software, see Chapter 5,
Troubleshooting.