Corporate Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 526-4100
Catalyst 6500 Series Switch Module
Installation Guide
October 2003
Customer Order Number: DOC-7815725=
Text Part Number: 78-15725-02
Vedere la pagina 0
1 2 3 4 5 6 ... 193 194

Sommario

Pagina 1 - Installation Guide

Corporate HeadquartersCisco Systems, Inc.170 West Tasman DriveSan Jose, CA 95134-1706USAhttp://www.cisco.comTel: 408 526-4000800 553-NETS (6387)Fax: 4

Pagina 2

ContentsxCatalyst 6500 Series Switch Module Installation Guide78-15725-02APPENDIX A Technical Specifications A-1Module Specifications A-1Regulatory St

Pagina 3

Chapter 1 Product OverviewVoice-Related Modules1-76Catalyst 6500 Series Switch Module Installation Guide78-15725-02The Communications Media Modul

Pagina 4

1-77Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewVoice-Related ModulesFor additional information, re

Pagina 5 - CONTENTS

Chapter 1 Product OverviewVoice-Related Modules1-78Catalyst 6500 Series Switch Module Installation Guide78-15725-02Ta b l e 1 - 1 9 C M M S TAT

Pagina 6

1-79Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewVoice-Related ModulesFigure 1-50 and Figure 1-51 sh

Pagina 7

Chapter 1 Product OverviewVoice-Related Modules1-80Catalyst 6500 Series Switch Module Installation Guide78-15725-028-Port T1/E1 PSTN Interface Mo

Pagina 8

1-81Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewVoice-Related ModulesFigure 1-52 8-Port T1/E1 PSTN

Pagina 9 - 3 Installing the Module 3-1

Chapter 1 Product OverviewVoice-Related Modules1-82Catalyst 6500 Series Switch Module Installation Guide78-15725-0224-Port FXS Analog Interface M

Pagina 10 - 78-15725-02

1-83Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewVoice-Related ModulesNote When installing the WS-X6

Pagina 11 - Audience

Chapter 1 Product OverviewPort Addresses1-84Catalyst 6500 Series Switch Module Installation Guide78-15725-02Port AddressesEach port (or interface

Pagina 12 - Conventions

1-85Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewPort AddressesPhysical Interface AddressesPhysical

Pagina 13

xiCatalyst 6500 Series Switch Module Installation Guide78-15725-02PrefaceThis preface describes who should read the Catalyst 6500 Series Switch Module

Pagina 14 - Varoitus

Chapter 1 Product OverviewPort Addresses1-86Catalyst 6500 Series Switch Module Installation Guide78-15725-02Interface ports maintain the same add

Pagina 15 - Avvertenza

1-87Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewHot Swapping Supervisor Engines and Switching Modul

Pagina 16 - ¡Advertencia!

Chapter 1 Product OverviewPower Management and Environmental Monitoring1-88Catalyst 6500 Series Switch Module Installation Guide78-15725-02Power

Pagina 17 - Varning!

CHAPTER2-1Catalyst 6500 Series Switch Module Installation Guide78-15725-022Preparing for InstallationThis chapter describes how to prepare your site b

Pagina 18

Chapter 2 Preparing for InstallationDetermining Cable Distances2-2Catalyst 6500 Series Switch Module Installation Guide78-15725-02Determining Cab

Pagina 19 - Obtaining Documentation

2-3Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 2 Preparing for InstallationDetermining Cable DistancesATMThe maximum

Pagina 20 - Ordering Documentation

Chapter 2 Preparing for InstallationDetermining Cable Distances2-4Catalyst 6500 Series Switch Module Installation Guide78-15725-02Ethernet and Fa

Pagina 21 - Documentation Feedback

2-5Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 2 Preparing for InstallationDetermining Cable DistancesGigabit Etherne

Pagina 22 - Opening a TAC Case

Chapter 2 Preparing for InstallationDetermining Cable Distances2-6Catalyst 6500 Series Switch Module Installation Guide78-15725-02Table 2-6 Gigab

Pagina 23 - TAC Case Priority Definitions

2-7Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 2 Preparing for InstallationDetermining Cable Distances10-Gigabit Ethe

Pagina 24

PrefaceOrganizationxiiCatalyst 6500 Series Switch Module Installation Guide78-15725-02OrganizationThis publication is organized as follows:Conventions

Pagina 25 - Product Overview

Chapter 2 Preparing for InstallationDetermining Cable Distances2-8Catalyst 6500 Series Switch Module Installation Guide78-15725-02Table 2-8 10-Gi

Pagina 26 - Catalyst 6000 Series Switches

2-9Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 2 Preparing for InstallationDetermining Cable DistancesPatch CordWhen

Pagina 27

Chapter 2 Preparing for InstallationDetermining Cable Distances2-10Catalyst 6500 Series Switch Module Installation Guide78-15725-02Note Cisco Gig

Pagina 28 - Catalyst 6500 Series Switches

2-11Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 2 Preparing for InstallationDetermining Cable DistancesFigure 2-2 Pat

Pagina 29

Chapter 2 Preparing for InstallationDetermining Cable Distances2-12Catalyst 6500 Series Switch Module Installation Guide78-15725-02MMF cable has

Pagina 30

2-13Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 2 Preparing for InstallationDetermining Cable Distancespatch cords fo

Pagina 31

Chapter 2 Preparing for InstallationDetermining Cable Distances2-14Catalyst 6500 Series Switch Module Installation Guide78-15725-02Table 2-10 lis

Pagina 32 - Supervisor Engines

2-15Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 2 Preparing for InstallationDetermining Cable Distances• MT-RJ fiber-

Pagina 33

Chapter 2 Preparing for InstallationPort Densities2-16Catalyst 6500 Series Switch Module Installation Guide78-15725-02Figure 2-7 LC Fiber-Optic C

Pagina 34

2-17Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 2 Preparing for InstallationPort DensitiesTable 2-11 Catalyst 6000 Se

Pagina 35

xiiiCatalyst 6500 Series Switch Module Installation Guide78-15725-02PrefaceConventionsNotes use the following conventions:Note Means reader take note.

Pagina 36

Chapter 2 Preparing for InstallationGigabit Interface Converters2-18Catalyst 6500 Series Switch Module Installation Guide78-15725-02Gigabit Inter

Pagina 37 - CONSOLE Port

2-19Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 2 Preparing for InstallationGigabit Interface ConvertersWS-G5483 Copp

Pagina 38

Chapter 2 Preparing for InstallationGigabit Interface Converters2-20Catalyst 6500 Series Switch Module Installation Guide78-15725-02WS-G5484, WS-

Pagina 39 - Uplink Ports

2-21Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 2 Preparing for InstallationGigabit Interface ConvertersCoarse Wave D

Pagina 40

Chapter 2 Preparing for InstallationGigabit Interface Converters2-22Catalyst 6500 Series Switch Module Installation Guide78-15725-02SFP Optical T

Pagina 41

2-23Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 2 Preparing for InstallationGigabit Interface Converters1000BASE-T SF

Pagina 42

Chapter 2 Preparing for InstallationGigabit Interface Converters2-24Catalyst 6500 Series Switch Module Installation Guide78-15725-02CWDM SFP Opti

Pagina 43

2-25Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 2 Preparing for InstallationGigabit Interface ConvertersFigure 2-14 C

Pagina 44 - (WS-X6024-10FL-MT)

Chapter 2 Preparing for InstallationSoftware Requirements2-26Catalyst 6500 Series Switch Module Installation Guide78-15725-02Figure 2-15 XenPak O

Pagina 45 - (WS-X6148V-GE-TX)

CHAPTER3-1Catalyst 6500 Series Switch Module Installation Guide78-15725-023Installing the ModuleThis chapter describes how to install and verify the o

Pagina 46 - (WS-X6148-RJ21V)

PrefaceConventionsxivCatalyst 6500 Series Switch Module Installation Guide78-15725-02Warnings use the following conventions:Statement 1071—Warning Def

Pagina 47 - (WS-X6148-RJ45V)

Chapter 3 Installing the ModuleRequired Tools3-2Catalyst 6500 Series Switch Module Installation Guide78-15725-02WarningDuring this procedure, wea

Pagina 48 - (WS-X6224-100FX-MT)

3-3Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 3 Installing the ModuleInstalling a Supervisor Engine or a Switching M

Pagina 49 - (WS-X6248-TEL)

Chapter 3 Installing the ModuleInstalling a Supervisor Engine or a Switching Module3-4Catalyst 6500 Series Switch Module Installation Guide78-157

Pagina 50 - (WS-X6324-100FX-MM)

3-5Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 3 Installing the ModuleInstalling a Supervisor Engine or a Switching M

Pagina 51 - (WS-X6324-100FX-SM)

Chapter 3 Installing the ModuleInstalling a Supervisor Engine or a Switching Module3-6Catalyst 6500 Series Switch Module Installation Guide78-157

Pagina 52 - (WS-X6348-RJ21V)

3-7Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 3 Installing the ModuleInstalling a Supervisor Engine or a Switching M

Pagina 53 - (WS-X6348-RJ-45)

Chapter 3 Installing the ModuleInstalling a Supervisor Engine or a Switching Module3-8Catalyst 6500 Series Switch Module Installation Guide78-157

Pagina 54 - (WS-X6348-RJ45V)

3-9Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 3 Installing the ModuleInstalling a Supervisor Engine or a Switching M

Pagina 55 - (WS-X6548-GE-TX)

Chapter 3 Installing the ModuleInstalling a Supervisor Engine or a Switching Module3-10Catalyst 6500 Series Switch Module Installation Guide78-15

Pagina 56 - (WS-X6548V-GE-TX)

3-11Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 3 Installing the ModuleInstalling a Supervisor Engine or a Switching

Pagina 57 - Module (WS-X6548-RJ-21)

xvCatalyst 6500 Series Switch Module Installation Guide78-15725-02PrefaceConventionsAttentionIMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d'av

Pagina 58 - Module (WS-X6548-RJ-45)

Chapter 3 Installing the ModuleRemoving the Supervisor Engine or a Switching Module3-12Catalyst 6500 Series Switch Module Installation Guide78-15

Pagina 59 - Module (WS-X6748-GE-TX)

3-13Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 3 Installing the ModuleRemoving the Supervisor Engine or a Switching

Pagina 60

Chapter 3 Installing the ModuleRemoving the Supervisor Engine or a Switching Module3-14Catalyst 6500 Series Switch Module Installation Guide78-15

Pagina 61

3-15Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 3 Installing the ModuleConnecting to the Console Port—Supervisor Engi

Pagina 62

Chapter 3 Installing the ModuleConnecting to the Uplink Ports—Supervisor Engine Only3-16Catalyst 6500 Series Switch Module Installation Guide78-1

Pagina 63 - 1000BASE-X GBIC ports

3-17Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 3 Installing the ModuleUsing Flash PC CardsTo connect to the supervis

Pagina 64

Chapter 3 Installing the ModuleUsing Flash PC Cards3-18Catalyst 6500 Series Switch Module Installation Guide78-15725-02This section describes how

Pagina 65

3-19Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 3 Installing the ModuleVerifying the InstallationInstalling and Remov

Pagina 66 - Installed

Chapter 3 Installing the ModuleVerifying the Installation3-20Catalyst 6500 Series Switch Module Installation Guide78-15725-02Verifying Newly Inst

Pagina 67

3-21Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 3 Installing the ModuleVerifying the InstallationMod Sub-Type

Pagina 68 - (WS-X6516-GE-TX)

PrefaceConventionsxviCatalyst 6500 Series Switch Module Installation Guide78-15725-02AdvarselVIKTIGE SIKKERHETSINSTRUKSJONERDette advarselssymbolet be

Pagina 69

Chapter 3 Installing the ModuleWhat To Do After Installing Modules and Verifying Connectivity3-22Catalyst 6500 Series Switch Module Installation

Pagina 70

A-1Catalyst 6500 Series Switch Module Installation Guide78-15725-02APPENDIXATechnical SpecificationsNote In this appendix, the term Catalyst 6500 seri

Pagina 71 - Ethernet Module LEDs

Appendix A Technical SpecificationsRegulatory Standards ComplianceA-2Catalyst 6500 Series Switch Module Installation Guide78-15725-02Regulatory S

Pagina 72 - ATM Modules

B-1Catalyst 6500 Series Switch Module Installation Guide78-15725-02APPENDIXBCable and Connector SpecificationsThis appendix lists the cable and connec

Pagina 73

Appendix B Cable and Connector SpecificationsRJ-21 ConnectorB-2Catalyst 6500 Series Switch Module Installation Guide78-15725-02RJ-21 ConnectorThe

Pagina 74

B-3Catalyst 6500 Series Switch Module Installation Guide78-15725-02Appendix B Cable and Connector SpecificationsRJ-21 ConnectorTable B-1 lists th

Pagina 75 - ATM Module LEDs

Appendix B Cable and Connector SpecificationsRJ-21 (WS-X6624-FXS Only)B-4Catalyst 6500 Series Switch Module Installation Guide78-15725-02RJ-21 (W

Pagina 76 - FlexWAN Module (WS-X6182-2PA)

B-5Catalyst 6500 Series Switch Module Installation Guide78-15725-02Appendix B Cable and Connector SpecificationsRJ-45 ConnectorRJ-45 ConnectorThe

Pagina 77 - WAN Port Adapters

Appendix B Cable and Connector SpecificationsRJ-45 ConnectorB-6Catalyst 6500 Series Switch Module Installation Guide78-15725-02Inline power for I

Pagina 78 - STATUS LED

B-7Catalyst 6500 Series Switch Module Installation Guide78-15725-02Appendix B Cable and Connector SpecificationsRJ-45 ConnectorFigure B-3 Twisted

Pagina 79

xviiCatalyst 6500 Series Switch Module Installation Guide78-15725-02PrefaceConventionsVarning!VIKTIGA SÄKERHETSANVISNINGARDenna varningssignal signale

Pagina 80 - MODE switch

Appendix B Cable and Connector SpecificationsSupervisor Engine Console Port Signals and PinoutsB-8Catalyst 6500 Series Switch Module Installation

Pagina 81

B-9Catalyst 6500 Series Switch Module Installation Guide78-15725-02Appendix B Cable and Connector SpecificationsSupervisor Engine Console Port Si

Pagina 82 - Network Analysis Modules

Appendix B Cable and Connector SpecificationsSupervisor Engine Console Port Signals and PinoutsB-10Catalyst 6500 Series Switch Module Installatio

Pagina 83 - • Netflow Data Export (NDE)

B-11Catalyst 6500 Series Switch Module Installation Guide78-15725-02Appendix B Cable and Connector SpecificationsSupervisor Engine Console Port S

Pagina 84 - SHUTDOWN button

Appendix B Cable and Connector SpecificationsSupervisor Engine Console Port Signals and PinoutsB-12Catalyst 6500 Series Switch Module Installatio

Pagina 85

B-13Catalyst 6500 Series Switch Module Installation Guide78-15725-02Appendix B Cable and Connector SpecificationsSupervisor Engine Console Port S

Pagina 86

Appendix B Cable and Connector SpecificationsFiber-Optic ConnectorsB-14Catalyst 6500 Series Switch Module Installation Guide78-15725-02Fiber-Opti

Pagina 87

B-15Catalyst 6500 Series Switch Module Installation Guide78-15725-02Appendix B Cable and Connector SpecificationsFiber-Optic ConnectorsAlways mak

Pagina 88

Appendix B Cable and Connector SpecificationsFiber-Optic ConnectorsB-16Catalyst 6500 Series Switch Module Installation Guide78-15725-02When you a

Pagina 89

B-17Catalyst 6500 Series Switch Module Installation Guide78-15725-02Appendix B Cable and Connector SpecificationsFiber-Optic ConnectorsFigure B-8

Pagina 90 - (WS-SVC-IPSEC-1)

PrefaceConventionsxviiiCatalyst 6500 Series Switch Module Installation Guide78-15725-02

Pagina 91

Appendix B Cable and Connector SpecificationsFiber-Optic ConnectorsB-18Catalyst 6500 Series Switch Module Installation Guide78-15725-02To clean t

Pagina 92 - • The module is disabled

IN-1Catalyst 6500 Series Switch Module Installation Guide78-15725-02INDEXNumerics1000BASE-LX/LHchannel insertion loss (table)2-7transmission distances

Pagina 93 - (HD) LED

IndexIN-2Catalyst 6500 Series Switch Module Installation Guide78-15725-02Bblank module carriers 3-3boot Flash 1-7CcablesATM distance limitations2-3Cat

Pagina 94

IN-3Catalyst 6500 Series Switch Module Installation Guide78-15725-02IndexCommunication Media Moduledescription1-75E1 interface module front panel (fig

Pagina 95 - RJ-45 (Test)

IndexIN-4Catalyst 6500 Series Switch Module Installation Guide78-15725-02Ethernet cables 2-4Fast Etherent cables 2-4Gigabit Ethernet cables 2-6DMDdesc

Pagina 96 - Switch Fabric Modules

IN-5Catalyst 6500 Series Switch Module Installation Guide78-15725-02IndexPCMCIA slots 1-15port mode switches 1-14Reset buttons 1-13switch load meters

Pagina 97 - LCD display

IndexIN-6Catalyst 6500 Series Switch Module Installation Guide78-15725-02link spans, excessive 2-13LX/LH GBIC 2-9, 2-14MMAC addressallocation1-86descr

Pagina 98

IN-7Catalyst 6500 Series Switch Module Installation Guide78-15725-02IndexPPacket-over-SONETsee POSpatch cordconfiguration example2-10differential mode

Pagina 99

IndexIN-8Catalyst 6500 Series Switch Module Installation Guide78-15725-02rollover cable B-9RX LEDATM modules description (table)1-51SSC connectordescr

Pagina 100 - Interface Module slots

IN-9Catalyst 6500 Series Switch Module Installation Guide78-15725-02IndexSwitch Fabric ModulesCatalyst 6500 series switches1-5features 1-72, 1-73front

Pagina 101 - with CRC

xixCatalyst 6500 Series Switch Module Installation Guide78-15725-02PrefaceRelated DocumentationRelated DocumentationFor instructions on installing and

Pagina 102

IndexIN-10Catalyst 6500 Series Switch Module Installation Guide78-15725-02WS-SVC-CMM6-port E1 interface module1-796-port T1 interface module 1-79descr

Pagina 103 - Receive port LEDs

IN-11Catalyst 6500 Series Switch Module Installation Guide78-15725-02IndexWS-X6148-RJ45Vdescription1-23front panel (figure) 1-24inline power 1-23LEDs

Pagina 104 - Voice-Related Modules

IndexIN-12Catalyst 6500 Series Switch Module Installation Guide78-15725-02WS-X6248-TELdescription1-25front panel (figure) 1-25LEDs 1-25WS-X6302-MSM 1-

Pagina 105

IN-13Catalyst 6500 Series Switch Module Installation Guide78-15725-02IndexWS-X6500-SFM2description1-73front panel (figure) 1-74LCD display 1-74LEDs 1-

Pagina 106 - Statement 1031

IndexIN-14Catalyst 6500 Series Switch Module Installation Guide78-15725-02WS-X6548V-GE-TXdescription1-32front panel (figure) 1-33inline power 1-32LEDs

Pagina 107 - 24 PORT FXS ANALOG STATION

THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMM

Pagina 108 - Port Addresses

PrefaceObtaining DocumentationxxCatalyst 6500 Series Switch Module Installation Guide78-15725-02Cisco.comYou can access the most current Cisco documen

Pagina 109 - Physical Interface Addresses

xxiCatalyst 6500 Series Switch Module Installation Guide78-15725-02PrefaceDocumentation FeedbackYou can order Cisco documentation in these ways:• Regi

Pagina 110 - MAC Addresses

PrefaceObtaining Technical AssistancexxiiCatalyst 6500 Series Switch Module Installation Guide78-15725-02Cisco TAC WebsiteThe Cisco TAC website (http:

Pagina 111 - Switching Modules

xxiiiCatalyst 6500 Series Switch Module Installation Guide78-15725-02PrefaceObtaining Additional Publications and InformationTAC Case Priority Definit

Pagina 112

PrefaceObtaining Additional Publications and InformationxxivCatalyst 6500 Series Switch Module Installation Guide78-15725-02investment. Included are n

Pagina 113 - Preparing for Installation

CHAPTER1-1Catalyst 6500 Series Switch Module Installation Guide78-15725-021Product OverviewThis chapter describes the Catalyst 6000 series switches, t

Pagina 114 - Determining Cable Distances

Chapter 1 Product OverviewCatalyst 6000 Series Switches1-2Catalyst 6500 Series Switch Module Installation Guide78-15725-02• IPSec VPN Acceleratio

Pagina 115

1-3Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewCatalyst 6000 Series SwitchesNote The uplink ports a

Pagina 116 - Ethernet and Fast Ethernet

Chapter 1 Product OverviewCatalyst 6500 Series Switches1-4Catalyst 6500 Series Switch Module Installation Guide78-15725-02Catalyst 6500 Series Sw

Pagina 117 - Gigabit Ethernet

1-5Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewCatalyst 6500 Series Switches–Two additional switchi

Pagina 118

NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED “AS IS” WITH ALL FAULTS. CISCO AND THE ABOV

Pagina 119 - 10-Gigabit Ethernet

Chapter 1 Product OverviewCatalyst 6500 Series Switches1-6Catalyst 6500 Series Switch Module Installation Guide78-15725-02Note For redundancy, yo

Pagina 120

1-7Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewCatalyst 6500 Series SwitchesComponent Hot-SwappingM

Pagina 121 - Patch Cord

Chapter 1 Product OverviewSupervisor Engines1-8Catalyst 6500 Series Switch Module Installation Guide78-15725-02Supervisor EnginesThis section des

Pagina 122 - Patch Cord Installation

1-9Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewSupervisor EnginesWS-X6K-SUP1A-MSFC • Supervisor Eng

Pagina 123 - Differential Mode Delay

Chapter 1 Product OverviewSupervisor Engines1-10Catalyst 6500 Series Switch Module Installation Guide78-15725-02Figure 1-1 shows the front panel

Pagina 124 - Laser transmission

1-11Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewSupervisor EnginesFigure 1-1 Supervisor Engine 1 Fr

Pagina 125

Chapter 1 Product OverviewSupervisor Engines1-12Catalyst 6500 Series Switch Module Installation Guide78-15725-02LEDsThe LEDs on the supervisor en

Pagina 126

1-13Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewSupervisor EnginesRESET ButtonThe RESET button allo

Pagina 127 - RJ-45 (both ends)

Chapter 1 Product OverviewSupervisor Engines1-14Catalyst 6500 Series Switch Module Installation Guide78-15725-02Note EIA/TIA-232 and EIA/TIA-449

Pagina 128 - Port Densities

1-15Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewSupervisor EnginesFor more information on using the

Pagina 130 - Gigabit Interface Converters

Chapter 1 Product Overview10/100 and 10/100/1000 Ethernet Switching Modules1-16Catalyst 6500 Series Switch Module Installation Guide78-15725-02Fo

Pagina 131 - WS-G5483 Copper GBIC

1-17Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product Overview10/100 and 10/100/1000 Ethernet Switching Modules•

Pagina 132 - WS-G5487)

Chapter 1 Product Overview10/100 and 10/100/1000 Ethernet Switching Modules1-18Catalyst 6500 Series Switch Module Installation Guide78-15725-02Ta

Pagina 133 - Table 2-13 CWDM GBICs

1-19Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product Overview10/100 and 10/100/1000 Ethernet Switching ModulesWS

Pagina 134

Chapter 1 Product Overview10/100 and 10/100/1000 Ethernet Switching Modules1-20Catalyst 6500 Series Switch Module Installation Guide78-15725-0224

Pagina 135 - 1000BASE-T SFP Modules

1-21Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product Overview10/100 and 10/100/1000 Ethernet Switching Modules48

Pagina 136

Chapter 1 Product Overview10/100 and 10/100/1000 Ethernet Switching Modules1-22Catalyst 6500 Series Switch Module Installation Guide78-15725-02•

Pagina 137 - S/N: OH1233456

1-23Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product Overview10/100 and 10/100/1000 Ethernet Switching Modules•

Pagina 138 - Software Requirements

Chapter 1 Product Overview10/100 and 10/100/1000 Ethernet Switching Modules1-24Catalyst 6500 Series Switch Module Installation Guide78-15725-02Th

Pagina 139 - Installing the Module

1-25Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product Overview10/100 and 10/100/1000 Ethernet Switching Modules48

Pagina 140 - Required Tools

vCatalyst 6500 Series Switch Module Installation Guide78-15725-02CONTENTSPreface xiAudience xiOrganization xiiConventions xiiStatement 1071—Warning De

Pagina 141 - Statement 1051

Chapter 1 Product Overview10/100 and 10/100/1000 Ethernet Switching Modules1-26Catalyst 6500 Series Switch Module Installation Guide78-15725-0248

Pagina 142

1-27Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product Overview10/100 and 10/100/1000 Ethernet Switching ModulesFi

Pagina 143

Chapter 1 Product Overview10/100 and 10/100/1000 Ethernet Switching Modules1-28Catalyst 6500 Series Switch Module Installation Guide78-15725-0248

Pagina 144 - Horizontal slots

1-29Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product Overview10/100 and 10/100/1000 Ethernet Switching Modules48

Pagina 145 - Chapter 1

Chapter 1 Product Overview10/100 and 10/100/1000 Ethernet Switching Modules1-30Catalyst 6500 Series Switch Module Installation Guide78-15725-0248

Pagina 146 - Vertical slots

1-31Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product Overview10/100 and 10/100/1000 Ethernet Switching Modules24

Pagina 147

Chapter 1 Product Overview10/100 and 10/100/1000 Ethernet Switching Modules1-32Catalyst 6500 Series Switch Module Installation Guide78-15725-02Fi

Pagina 148

1-33Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product Overview10/100 and 10/100/1000 Ethernet Switching ModulesFi

Pagina 149

Chapter 1 Product Overview10/100 and 10/100/1000 Ethernet Switching Modules1-34Catalyst 6500 Series Switch Module Installation Guide78-15725-0248

Pagina 150 - All ejector levers flush

1-35Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product Overview10/100 and 10/100/1000 Ethernet Switching Modules48

Pagina 151

ContentsviCatalyst 6500 Series Switch Module Installation Guide78-15725-02CONSOLE PORT MODE Switch 1-14Switch Load 1-15PCMCIA Slot 1-15Uplink Ports 1-

Pagina 152

Chapter 1 Product OverviewGigabit Ethernet Switching Modules1-36Catalyst 6500 Series Switch Module Installation Guide78-15725-02Gigabit Ethernet

Pagina 153 - Connecting a Terminal

1-37Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewGigabit Ethernet Switching ModulesWS-X6501-10GEX4 S

Pagina 154 - Connecting a Modem

Chapter 1 Product OverviewGigabit Ethernet Switching Modules1-38Catalyst 6500 Series Switch Module Installation Guide78-15725-02Note These module

Pagina 155 - Using Flash PC Cards

1-39Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewGigabit Ethernet Switching ModulesFigure 1-25 8-Por

Pagina 156

Chapter 1 Product OverviewGigabit Ethernet Switching Modules1-40Catalyst 6500 Series Switch Module Installation Guide78-15725-0216-Port Gigabit E

Pagina 157 - Verifying the Installation

1-41Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewGigabit Ethernet Switching Modules16-Port Gigabit E

Pagina 158

Chapter 1 Product OverviewGigabit Ethernet Switching Modules1-42Catalyst 6500 Series Switch Module Installation Guide78-15725-021-Port 10-Gigabit

Pagina 159

1-43Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewGigabit Ethernet Switching ModulesThe WS-X6516-GBIC

Pagina 160 - Connectivity

Chapter 1 Product OverviewGigabit Ethernet Switching Modules1-44Catalyst 6500 Series Switch Module Installation Guide78-15725-02Figure 1-32 16-Po

Pagina 161 - Technical Specifications

1-45Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewGigabit Ethernet Switching ModulesFigure 1-34 4-Por

Pagina 162

viiCatalyst 6500 Series Switch Module Installation Guide78-15725-02Contents48-Port 10/100/1000BASE-T Ethernet Switching Module (WS-X6548V-GE-TX)1-3248

Pagina 163 - APPENDIX

Chapter 1 Product OverviewGigabit Ethernet Switching Modules1-46Catalyst 6500 Series Switch Module Installation Guide78-15725-0216-Port Gigabit E

Pagina 164 - RJ-21 Connector

1-47Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewEthernet Module LEDsThe front panel LEDs are descri

Pagina 165

Chapter 1 Product OverviewATM Modules1-48Catalyst 6500 Series Switch Module Installation Guide78-15725-02ATM ModulesThis section describes these

Pagina 166 - RJ-21 (WS-X6624-FXS Only)

1-49Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewATM Modules1-Port OC-12 ATM Module (WS-X6101-OC12-M

Pagina 167 - RJ-45 Connector

Chapter 1 Product OverviewATM Modules1-50Catalyst 6500 Series Switch Module Installation Guide78-15725-021-Port OC-12 ATM Module (WS-X6101-OC12-S

Pagina 168

1-51Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewATM ModulesATM Module LEDsThe ATM module front-pane

Pagina 169

Chapter 1 Product OverviewFlexWAN Module (WS-X6182-2PA)1-52Catalyst 6500 Series Switch Module Installation Guide78-15725-02FlexWAN Module (WS-X61

Pagina 170

1-53Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewFlexWAN Module (WS-X6182-2PA)For more information a

Pagina 171 - Identifying a Rollover Cable

Chapter 1 Product OverviewMultilayer Switch Module (WS-X6302-MSM)1-54Catalyst 6500 Series Switch Module Installation Guide78-15725-02Figure 1-39

Pagina 172 - Pin 1 and pin 8

1-55Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewMultilayer Switch Module (WS-X6302-MSM)Table 1-10 C

Pagina 173 - (DB-25 Adapter)

ContentsviiiCatalyst 6500 Series Switch Module Installation Guide78-15725-02Network Analysis Modules 1-58Network Analysis Module (WS-SVC-NAM-1) 1-59Ne

Pagina 174 - Modem Adapter

Chapter 1 Product OverviewMultilayer Switch Module (WS-X6302-MSM)1-56Catalyst 6500 Series Switch Module Installation Guide78-15725-02The MSM fron

Pagina 175 - (Modem Adapter)

1-57Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewMultilayer Switch Module (WS-X6302-MSM)The CONSOLE

Pagina 176 - Fiber-Optic Connectors

Chapter 1 Product OverviewNetwork Analysis Modules1-58Catalyst 6500 Series Switch Module Installation Guide78-15725-02Use the CONSOLE PORT MODE s

Pagina 177 - MT-RJ Connectors

1-59Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewNetwork Analysis ModulesNetwork Analysis Module (WS

Pagina 178 - LC Connectors

Chapter 1 Product OverviewNetwork Analysis Modules1-60Catalyst 6500 Series Switch Module Installation Guide78-15725-02Figure 1-41 Network Analysi

Pagina 179

1-61Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewNetwork Analysis ModulesNetwork Analysis Module (WS

Pagina 180

Chapter 1 Product OverviewNetwork Analysis Modules1-62Catalyst 6500 Series Switch Module Installation Guide78-15725-02Figure 1-42 Network Analysi

Pagina 181 - Numerics

1-63Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewFirewall Services Module (WS-SVC-FWM-1-K9)Firewall

Pagina 182

Chapter 1 Product OverviewFirewall Services Module (WS-SVC-FWM-1-K9)1-64Catalyst 6500 Series Switch Module Installation Guide78-15725-02• Securit

Pagina 183

1-65Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewFirewall Services Module (WS-SVC-FWM-1-K9)The front

Pagina 184

ixCatalyst 6500 Series Switch Module Installation Guide78-15725-02ContentsPatch Cord 2-9Differential Mode Delay 2-11Console Port Cabling Specification

Pagina 185

Chapter 1 Product OverviewIPSec VPN Acceleration Services Module (WS-SVC-IPSEC-1)1-66Catalyst 6500 Series Switch Module Installation Guide78-1572

Pagina 186

1-67Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewIPSec VPN Acceleration Services Module (WS-SVC-IPSE

Pagina 187

Chapter 1 Product OverviewIntrusion Detection System Module (WS-X6381-IDS)1-68Catalyst 6500 Series Switch Module Installation Guide78-15725-02For

Pagina 188

1-69Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewIntrusion Detection System Module (WS-X6381-IDS)The

Pagina 189

Chapter 1 Product OverviewIntrusion Detection System Module (WS-X6381-IDS)1-70Catalyst 6500 Series Switch Module Installation Guide78-15725-02The

Pagina 190

1-71Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewContent Switching Module (WS-X6066-SLB-APC)Content

Pagina 191

Chapter 1 Product OverviewSwitch Fabric Modules1-72Catalyst 6500 Series Switch Module Installation Guide78-15725-02Switch Fabric ModulesThis sect

Pagina 192

1-73Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewSwitch Fabric Modulesmodule, and the module install

Pagina 193

Chapter 1 Product OverviewSwitch Fabric Modules1-74Catalyst 6500 Series Switch Module Installation Guide78-15725-02Note The Switch Fabric 2 modul

Pagina 194

1-75Catalyst 6500 Series Switch Module Installation Guide78-15725-02Chapter 1 Product OverviewVoice-Related ModulesVoice-Related ModulesThis sect

Commenti su questo manuale