2-458
Catalyst 2950 and Catalyst 2955 Switch Command Reference
0L-10102-02
Chapter 2 Catalyst 2950 and 2955 Cisco IOS Commands
spanning-tree mst max-hops
spanning-tree mst max-hops
Use the spanning-tree mst max-hops global configuration command to set the number of hops in a
region before the bridge protocol data unit (BPDU) is discarded and the information held for a port is
aged. Use the no form of this command to return to the default setting.
spanning-tree mst max-hops hop-count
no spanning-tree mst max-hops
Syntax Description
Defaults The default is 20 hops.
Command Modes Global configuration
Command History
Usage Guidelines The root switch of the instance always sends a BPDU (or M-record) with a cost of 0 and the hop count
set to the maximum value. When a switch receives this BPDU, it decrements the received remaining hop
count by one and propagates the decremented count as the remaining hop count in the generated
M-records. A switch discards the BPDU and ages the information held for the port when the count
reaches 0.
Changing the spanning-tree mst max-hops command affects all spanning-tree instances.
Examples This example shows how to set the spanning-tree max-hops to 10 for all MST instances:
Switch(config)# spanning-tree mst max-hops 10
You can verify your settings by entering the show spanning-tree mst privileged EXEC command.
Related Commands
hop-count Number of hops in a region before the BPDU is discarded. The range is 1 to 40 hops.
Release Modification
12.1(9)EA1 This command was introduced.
12.1(20)EA2 This command was added to the standard software image (SI).
Command Description
show spanning-tree mst Displays multiple spanning-tree (MST) information.
spanning-tree mst forward-time Sets the forward-delay time for all MST instances.
spanning-tree mst hello-time Sets the interval between hello BPDUs sent by root switch
configuration messages.
spanning-tree mst max-age Sets the interval between messages that the spanning tree
receives from the root switch.
Vedere la pagina 483
1 2 ... 479 480 481 482 483 484 485 486 487 488 489 ... 673 674

Commenti su questo manuale

Nessun commento

Verint Nextiva S2750e Series manuals

Owner’s manuals and user’s guides for Security access control systems Verint Nextiva S2750e Series.
We providing 2 pdf manuals Verint Nextiva S2750e Series for download free by document types: User's Guide, Installation Guide






More products and manuals for Security access control systems Verint

Models Document Type
None