Cisco SCE8000 Specifiche Pagina 455

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 778
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 454
2-415
Cisco SCE 8000 CLI Command Reference
Chapter 2 CLI Command Reference
show environment temperature
show environment temperature
Displays information about the temperature of the Cisco SCE platform.
show environment temperature
Syntax Description This command has no arguments or keywords.
Command Default None
Command Modes User EXEC
Command History This table includes the following release-specific history entries:
Usage Guidelines Authorization: viewer
Examples The following example shows how to use this command:
SCE8000>enable 5
Password:<cisco>
SCE8000>show environment temperature
Environment Temperature information:
---------------------
Slot 1: SCE8000-SCM-E
---------------------
scm[0].smc[0].max1668[0] - temperature device
INTERNAL status:
CurrStatus : OK (0000:00:02:15)
PrevStatus : <none> (----:--:--:--)
Sts# : 0 (access=35, fail=0)
TEMPERATURE status:
Name General CurrVal MinVal AvgVal MaxVal DevVal ErrL WrnL WrnH ErrH
CurrStatus dddd:hh:mm:ss PrevStatus dddd:hh:mm:ss Sts#
==========================================================================================
=======================================================
PCB_Upper local1 29C 29 29.0 29 0.0 -18 -8 60 75
OK 0000:00:02:15 ----------- ----:--:--:-- 0
DPT sd_1 39C 38 38.7 39 0.5 -8 2 74 89
OK 0000:00:02:15 ----------- ----:--:--:-- 0
CLS sd_2 33C 32 32.8 33 0.4 -8 2 63 78
OK 0000:00:02:15 ----------- ----:--:--:-- 0
SCE8000>
Release Modification
3.5.0 This command was introduced.
Vedere la pagina 454
1 2 ... 450 451 452 453 454 455 456 457 458 459 460 ... 777 778