2-415
Cisco SCE 8000 CLI Command Reference
Chapter 2 CLI Command Reference
show environment temperature
show environment temperature
Displays information about the temperature of the Cisco SCE platform.
show environment temperature
Syntax Description This command has no arguments or keywords.
Command Default None
Command Modes User EXEC
Command History This table includes the following release-specific history entries:
Usage Guidelines Authorization: viewer
Examples The following example shows how to use this command:
SCE8000>enable 5
Password:<cisco>
SCE8000>show environment temperature
Environment Temperature information:
---------------------
Slot 1: SCE8000-SCM-E
---------------------
scm[0].smc[0].max1668[0] - temperature device
INTERNAL status:
CurrStatus : OK (0000:00:02:15)
PrevStatus : <none> (----:--:--:--)
Sts# : 0 (access=35, fail=0)
TEMPERATURE status:
Name General CurrVal MinVal AvgVal MaxVal DevVal ErrL WrnL WrnH ErrH
CurrStatus dddd:hh:mm:ss PrevStatus dddd:hh:mm:ss Sts#
==========================================================================================
=======================================================
PCB_Upper local1 29C 29 29.0 29 0.0 -18 -8 60 75
OK 0000:00:02:15 ----------- ----:--:--:-- 0
DPT sd_1 39C 38 38.7 39 0.5 -8 2 74 89
OK 0000:00:02:15 ----------- ----:--:--:-- 0
CLS sd_2 33C 32 32.8 33 0.4 -8 2 63 78
OK 0000:00:02:15 ----------- ----:--:--:-- 0
SCE8000>
Release Modification
3.5.0 This command was introduced.