2-11
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 2 Alarm Troubleshooting
Alarm Logical Objects
Table 2-7 Alarm Logical Object Type Definitions
Type Definition
BITS
Building integrated timing supply (BITS) incoming references (BITS-1, BITS-2).
BPLANE
The backplane.
CE100T
The CE-100T-8 Ethernet card.
CEMR
The CE-MR-6 Ethernet card.
DS1
A DS-1 port on the 15310-CL-CTX, DS1-28/DS3-EC1-3, or DS1-84/DS3-EC1-3
card.
DS3
A DS-3 port on the 15310-CL-CTX, DS1-28/DS3-EC1-3, or DS1-84/DS3-EC1-3
card.
EC1
A EC-1 port on the 15310-CL-CTX, DS1-28/DS3-EC1-3, or DS1-84/DS3-EC1-3
card.
ENVALRM
An environmental alarm port.
EQPT
A card, its physical objects, and logical objects as they are located in any of the
noncommon card slots. The EQPT object is used for alarms that refer to the
card itself and all other objects on the card including ports, lines, synchronous
transport signal (STS), and virtual tributary (VT).
EXT-SREF
BITS outgoing references (SYNC-BITS1, SYNC-BITS2).
FAN
Fan located in the ONS 15310-CL or ONS 15310-MA shelf.
FUDC
SONET F1 byte user data channel for an ONS 15310-CL or ONS 15310-MA
ML-100T-8 Ethernet card.
ML100T
The ML-100T-8 Ethernet card.
NE
The entire network element.
NE-SREF
The timing status of the NE.
OCN
An OC-3 port or OC-12 port on the 15310-CL-CTX or CTX2500 card.
PPM
Pluggable port module (PPM, also called SFP).
RPRIF
Interface for Resilient Packet Ring technology as defined in IEEE 802.17b. Also
called RPR-IEEE.
PWR
The node power supply.
SHELF
The ONS 15310-CL or ONS 15310-MA shelf.
STSMON
STS alarm detection at the monitor point (upstream from the cross-connect).
Note The network element reports alarms or conditions on ingress ports of the
card. Alarms detected at the internal ports (TERM side) will be ingress
mapped to the MON side. The alarm profile entities of STSMON, if
available, should be changed to the same severity as the customized
severity for a specific STS alarm.
STSTRM
STS alarm detection at termination (downstream from the cross-connect).
Note The network element reports alarms or conditions on ingress ports of the
card. Alarms detected at the internal ports (TERM side) will be ingress
mapped to the MON side. The alarm profile entities of STSTRM, if
available, should be changed to the same severity as the customized
severity for a specific STS alarm.
Commenti su questo manuale