Cisco 15310-MA Guida alla Risoluzione dei Problemi Pagina 54

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 53
1-18
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 1 General Troubleshooting
Identify Points of Failure on an OC-N Circuit Path
h. Choose None from the Loopback Type column for the port being tested.
i. Choose the appropriate state (IS,AINS; OOS,DSBLD; or OOS,MT) from the Admin State column
for the port being tested.
j. Click Apply.
k. Click Yes in the confirmation dialog box.
l. Continue with the “1.3.2 Perform a Cross-Connect Loopback on the Source OC-N Port” procedure
on page 1-18.
1.3.2 Perform a Cross-Connect Loopback on the Source OC-N Port
The cross-connect loopback test occurs on the cross-connect portion of the controller card
(15310-CL-CTX or CTX2500 card) in a network circuit. Completing a successful cross-connect
loopback through the card isolates the possibility that the cross-connect is the cause of the faulty circuit.
Create the Cross-Connect Loopback on the Source OC-N Port
Step 1 Connect an optical test set to the port you are testing:
a. If you just completed the “1.3.1 Perform a Facility Loopback on a Source-Node OC-N Port”
procedure on page 1-17, leave the optical test set connected to the OC-N port in the source node.
b. If you are starting the current procedure without the optical test set connected to the OC-N port, use
appropriate cabling to attach the Tx and Rx terminals of the optical test set to the port you are
testing.
c. Adjust the test set accordingly.
Step 2 Use CTC to put the circuit being tested out of service:
a. In node view, click the Circuits tab.
b. Click the circuit and then click Edit.
c. In the Edit Circuit dialog box, click the State tab.
d. Choose OOS-MT from the Target Circuit Admin State drop-down list.
e. Click Apply.
f. Click Yes in the confirmation dialog box.
Step 3 Use CTC to set up the cross-connect loopback on the circuit being tested:
a. In node view, double-click the 15310-CL-CTX or CTX2500 to open the card view.
b. For the OC-N port, click the Maintenance > Optical > Loopback > SONET STS tabs.
c. Click the check box in the XC Loopback column for the port being tested.
d. Click Apply.
e. Click Yes in the confirmation dialog box.
Step 4 Continue with the “Test the Cross-Connect Loopback Circuit” procedure on page 1-19.