Cisco 15310-MA Guida alla Risoluzione dei Problemi Pagina 202

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 201
2-72
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 2 Alarm Troubleshooting
Alarm Procedures
2.7.97 FRCDSWTOTHIRD
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: EXT-SREF, NE-SREF
The Force Switch to Third Timing Source condition occurs when the user issues a Force command to
switch to a third timing source.
Note FRCDSWTOTHIRD is an informational condition. It does not require troubleshooting.
2.7.98 FRNGSYNC
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: NE-SREF
The Free Running Synchronization Mode condition occurs when the reporting ONS 15310-CL or
ONS 15310-MA is in free-run synchronization mode. External timing sources have been disabled and
the node is using its internal clock, or the node has lost its designated BITS timing source. After the
24-hour holdover period expires, timing slips could begin to occur on a node relying on an internal clock.
Note If the ONS 15310-CL or ONS 15310-MA is configured to operate from its internal clock, disregard the
FRNGSYNC condition.
Clear the FRNGSYNC Condition
Step 1 If the ONS 15310-CL or ONS 15310-MA is configured to operate from an external timing source, verify
that the BITS timing source is valid. Refer to the “Timing” chapter in the Cisco ONS 15310-CL and
Cisco ONS 15310-MA Reference Manual for more information about it.
Step 2 If the BITS source is valid, clear alarms related to the failures of the primary and secondary reference
sources, such as the “SYNCPRI” alarm on page 2-144 and the “SYNCSEC” alarm on page 2-145.
Step 3 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447).
2.7.99 FSTSYNC
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: NE-SREF
A Fast Start Synchronization Mode condition occurs when the ONS 15310-CL or ONS 15310-MA is
choosing a new timing reference. The previous timing reference has failed.
The FSTSYNC condition disappears after approximately 30 seconds. If the condition does not clear, log
into the Technical Support Website at http://www.cisco.com/techsupport for more information or call
Cisco TAC (1-800-553-2447).