Cisco 15310-MA Guida alla Risoluzione dei Problemi Pagina 321

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 320
4-13
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 4 Error Messages
WID-2176 Not all spans have the same OSPF area ID.
This will cause problems with protection switching. To
determine the OSPF area for a given span, click on the span and
the OSPF area will be displayed in the pane to the left of the
network map.
Refer to the warning message text.
WID-2178 Only one edit pane can be opened at a time. The existing pane
will be displayed.
Refer to the warning message text.
WID-2179 No update is available because the circuit has been deleted. Refer to the warning message text.
EID-2180 The CTC initialization failed during step {0}. CTC initialization has failed in the
specified step.
EID-2181 This link cannot be included because it originates from the
destination.
You must not include this link as it
originates from destination of a circuit. It is
against the path selection algorithm.
EID-2182 The value of {0} is invalid. The value of the specified item is invalid.
EID-2183 The circuit roll failed.
Bridge and roll is not supported on VCAT circuits.
Refer to the error message text.
EID-2184 Spanning Tree Protocol cannot be enabled on some ports
because the ports have been assigned an incompatible list of
VLANs.
You can view the VLAN/Spanning Tree table or reassign the
Ethernet port VLANs.
Refer to the error message text.
EID-2185 The VLANs on some ports cannot be assigned because they are
incompatible with the Spanning Tree Protocol.
You can view the VLAN/Spanning Tree table or reassign the
VLANs.
Refer to the error message text.
EID-2186 The software download failed on node {0}. The software could not be downloaded onto
the specified node.
EID-2187 The ring name cannot exceed {0} characters.
Please try again.
You must shorten the length of the ring
name.
EID-2188 The nodes in this ring do not support alphanumeric IDs. Please
use a ring ID between {0} and {1}.
The ring ID should not contain
alphanumeric characters, and must be in the
specified range.
EID-2189 The TL1 keyword “all” cannot be used as the ring name.
Please provide another name.
Refer to the error message text.
EID-2190 Adding this span will cause the ring to contain more nodes than
allowed.
You have reached the maximum number of
nodes allowed.
EID-2191 The ring name must not be empty. You must supply a ring name.
EID-2192 A valid route cannot be found for the circuit creation request. CTC could not complete the circuit creation
request either because there are no physical
links, or the bandwidth of the available
links are already reserved.
Table 4-1 Error Messages (continued)
Error/Warning
ID Error/Warning Message Description
Vedere la pagina 320