Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 2 Alarm Troubleshooting
Alarm Procedures
The Open Slot condition indicates that there is an open slot in the system shelf. Slot covers assist with
airflow and cooling.
Clear the OPEN-SLOT Condition
Step 1 To install a slot cover and clear this condition, refer to the procedures located in the “Install Hardware”
chapter of the Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide.
Step 2 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1 800 553-2447).
2.7.188 PDI-P
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: STSMON, STSTRM
A PDI-P is a set of application-specific codes indicating a signal label mismatch failure (SLMF) in the
ONS 15310-CL or ONS 15310-MA STS path overhead. The condition indicates to downstream
equipment that a defect is present in one or more of the directly mapped payloads contained in that STS
synchronous payload envelope (SPE). For example, the mismatch could occur in the overhead to the path
selector in a downstream node configured as part of a UPSR. The PDI-P codes appear in the STS Signal
Label (C2 byte).
An SLMF often occurs when the payload does not match what the signal label is reporting. The “AIS”
condition on page 2-20 often accompanies a PDI-P condition. If the PDI-P is the only condition reported
with the AIS, clearing PDI-P clears the AIS. PDI-P can also occur during an upgrade, but usually clears
itself and is not a valid condition.
A PDI-P condition reported on an OC-3 or OC-12 port supporting an ONS 15310-CL or ONS 15310-MA
Ethernet card circuit could result from the end-to-end Ethernet link integrity feature of the Ethernet card.
If the link integrity is the cause of the path defect, it is typically accompanied by the “CARLOSS
(EQPT)” alarm on page 2-39 reported against one or both Ethernet ports terminating the circuit. If this
is the case, clear the TPTFAIL and CARLOSS alarms to resolve the PDI-P condition.
Warning
Invisible laser radiation could be emitted from the end of the unterminated fiber cable or connector.
Do not stare into the beam directly with optical instruments. Viewing the laser output with certain
optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of
100 mm could pose an eye hazard.
Statement 1056
Warning
Use of controls, adjustments, or performing procedures other than those specified could result in
hazardous radiation exposure.
Statement 1057